- Medir comprimento de cabo coaxial
- PORTA S11
- DISPLAY > FORMAT > LOGMAG
- STIMULUS > START > 50 KHz (SEMPRE)
- STIMULUS > STOP > 2 GHz (COMPRIMENTO ATÉ 2 m)
- DISPLAY > TRANSFORM ou TDR > VELOCITY FACTOR
- DISPLAY > TRANSFORM ou TDR > LOW PASS IMPULSE
- DISPLAY > TRANSFORM ou TDR > TRANSFORM ON
- BUSCAR O MAIOR PICO E VERIFICAR O COMPRIMENTO NO DISPLAY
- PARA COMPRIMENTO DE +- 40 m DE CABO, USAR STOP 100 MHz
- PARA SABER A STOP FREQUENCY PARA O COMPRIMENTO DE CABO QUE DESEJA MEDIR
- PORTA S11
- DISPLAY > FORMAT > LOGMAG
- STIMULUS > START > 50 KHz (SEMPRE)
- STIMULUS > STOP > 2 GHz (COMPRIMENTO ATÉ 2 m)
- DISPLAY > TRANSFORM ou TDR > VELOCITY FACTOR
- DISPLAY > TRANSFORM ou TDR > LOW PASS IMPULSE
- DISPLAY > TRANSFORM ou TDR > TRANSFORM ON
- BUSCAR O MAIOR PICO E VERIFICAR O COMPRIMENTO NO DISPLAY
- PARA COMPRIMENTO DE +- 40 m DE CABO, USAR STOP 100 MHz
- PARA SABER A STOP FREQUENCY PARA O COMPRIMENTO DE CABO QUE DESEJA MEDIR
(6000/50m) * 0,66 = 80 MHz
(6000/60m) * 0,66 = 66 MHz
(6000/2m) * 0,66 = 2 GHz
VELOCITY FACTOR:- RG174: 66% (57% Empírico)
- RG58: 66%
- RG213 (Kmp): 82%
- RG174: 66% (57% Empírico)
- RG58: 66%
- RG213 (Kmp): 82%
Calculo para meia onda de cabo:
Calculo para meia onda de cabo:
( (Velocidade Luz)/(Frequencia * 0.66) ) / 2
99,831/F para cabos de 0,666
122,915/F para cabos rcg com fator 0,82